A Spatial Percolation-Theoretic Approach to Coverage and Connectivity

A Spatial Percolation-Theoretic Approach to Coverage and Connectivity by Habib M. Ammari.

AbstractThis chapter focuses on the problem of almost sure integrated coverage and connectivity in spatial wireless sensor networks. Precisely, it investigates critical density above which percolation deployment fields will surely occur. It discusses our solution to this using an approach that is totally different from one proposed for planar fields. Also, addresses a field.

Read A Spatial Percolation-Theoretic Approach to Coverage and Connectivity on OA.mg

Coverage and adequacy of ferrous sulfate supplementation in the prevention of anemia among children treated at health centers of Florianopolis, Santa Catarina

Coverage and adequacy of ferrous sulfate supplementation in the prevention of anemia among children treated at health centers of Florianopolis, Santa Catarina by Francieli Cembranel, Arlete Catarina Tittoni Corso, David Alejandro González-Chica.

OBJECTIVE To evaluate the National Program of Iron Supplementation (PNSF) coverage, compliance with directions for using this supplementation and association sociodemographic factors in children aged six to 18 months old registered 35 public health centers Florinópolis (Southern Brazil). METHODS Cross-sectional study secondary data obtained from information system Health Department Florianópolis, Santa Catarina, Brazil (Infosaúde). Data on ferrous sulfate variables were all PNSF Florianópolis 2010. STATA 11.0 software was used analyses. RESULTS The covered 6.3% (95%CI 5.9-6.7) children; regarding age at onset its frequency adequate only 2.4% cases 1.5-3.7). There no child’s gender, maternal education level ethnicity or distance home center. CONCLUSIONS This showed low coverage inadequate directions. Measures improve strategy are urgent.

Read Coverage and adequacy of ferrous sulfate supplementation in the prevention of anemia among children treated at health centers of Florianopolis, Santa Catarina on OA.mg

Comparable Worth: Limited Coverage and the Exacerbation of Inequality

Comparable Worth: Limited Coverage and the Exacerbation of Inequality by Robert S. Smith.

Citing relevant judicial decisions, the author argues that any application of comparable worth remedy for gender discrimination is likely to cover only certain groups workers. Most be covered are women who work governmental or large private employers in female-dominated jobs, and least small employers. The implementation would cause wages noncovered workers fall relative those workers, they might even absolutely. An analysis 1979 Current Population Survey data suggests most gain from fewer number, better paid, subjected no greater than lose.

Read Comparable Worth: Limited Coverage and the Exacerbation of Inequality on OA.mg

A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging

A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging by Martin P. Tornai, James E. Bowsher, C.N. Archer, Jörg Peter, Ronald J. Jaszczak, Lawrence R. MacDonald, Bradley E. Patt, Jan S. Iwanczyk.

Abstract A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast near chest wall. Initial measurements with various uptake ratios are presented. Methods: prototype tomograph constructed utilizing a compact gamma camera having field-of-view Results: As iteration number increased tomographically measured data at all polar angles, contrasts while signal-to-noise (SNRs) decreased expected way OSEM reconstruction. The rollover between contrast improvement SNR degradation lesion occurred two to three iterations. reconstructed yielded SNRs or without scatter correction that were >9 times better than planar scans. There up factor ∼2.5 increase total primary contamination photopeak window increasing tilt angle from 15° 45°, consistent more direct line-of-sight myocardial liver activity angle. Conclusion: This new, ultra-compact, dedicated system has potential providing valuable, fully 3D functional information about small, otherwise indeterminate as an adjunct diagnostic mammography.

Read A 3D gantry single photon emission tomograph with hemispherical coverage for dedicated breast imaging on OA.mg

Hepatitis B vaccination coverage levels among health care workers in Greek Military Hospitals.

Hepatitis B vaccination coverage levels among health care workers in Greek Military Hospitals. by Dimitris Tsoulas, Eleni Apostolopoulou.

Routine hepatitis B virus vaccination has been recommended to Health Care Workers since early ’90s because of their occupational exposure blood and body fluids. We conducted a prospec- tive cross sectional survey obtain an estimate coverage rate among nurs- ing personnel establish factors associated with levels. The study took place, at representative sample 245 nurses working in 7 Greek military hospitals using self-administrated questionnaires. For data analy- sis we used univariate multivariate logistic regression. self reported vaccina- tion was 75,5%. level higher registered than nurse aids (p

Read Hepatitis B vaccination coverage levels among health care workers in Greek Military Hospitals. on OA.mg